Consideration must be taken over where to install your Acoem Dynoptic Opacity, Dust or Particulate monitor. There are a number of points to evaluate before selecting the installation location on your stack or duct, including the following:
- Accessibility
- Vibration
- Gas flow within the stack
- Liquid aerosols
- Temperature
- Cable routes
- Earth connection
- Air purge tubing
- Legislation
- Ideally the measurement point should be located at least 5 duct diameters from the exhaust point, see image above. Where suitable sample planes exist in both vertical and horizontal sections of the duct, the vertical section is preferable.
- Please note. The heads should never be positioned at the bottom of a horizontal duct or angled duct, as particulate matter will fall under gravity towards the head and potentially cause the optics to become dirty more quickly.